Gencable.com
HomeContact Info
Spec Sheets Portable Cord Mining Cable Marine / Boat Cable Marine Wire Guide
Generator Cables Cam Connectors Generator Cable
Education / Guide
Cam Lock Pin & Sleeve Devices Lugs & Terminals
Camlock Connectors - Single Pole Locking Cam Type Connectors
LOCKING CAM CONNECTORS (CAMLOCK)
 
Buy camlocks online now!
Buy camlocks online now!

CAM CONNECTORS 

malecam.jpg (3720 bytes)
Male Cam


femcam.jpg (3452 bytes)
Female Cam
caps.jpg (8166 bytes)
End Caps

The industry standard for today's generator cable assemblies, cam connectors (also referred to as camlok, camlock, camloc, cam-lock, cam-loc) are designed to stand up to the physical and environmental abuse while facilitating a simple, yet secure connection method for large gensets.

Various manufacturers produce the cam connectors and they are all intermateable with each other which simplifies field installations and provides added safety. Intermateability is only possible with cams of the same series...again for safety reasons

  • 15 Series: Cable sizes #8 AWG-#2 AWG rated at 150 AMPS
  • 16 Series: Cable sizes #2 AWG-#4/0 AWG rated at 400 AMPS
  • 17 Series: Cable sizes 250 MCM-750 MCM rated at 690 AMPS

FEMALE TERMINAL CONNECTOR

ctlangle.jpg (3709 bytes)
Angle Style
  ctloffset.jpg (3855 bytes)
Offset Style
 

These connectors provide a simplified installation alternative for busbar connections. The female connector can be connected with a bolt, directly to the busbar facillitating the connection of a male cam connector. These connectors can be an alternative to pigtail extensions in certain installations and they are available in various colors in both the "Angle" and "Offset" designs.

PANEL RECEPTACLES   

screwpanmtfem.jpg (6780 bytes)
Threaded Stud Style
panelmtmale.jpg (9437 bytes)
Double Set Screw Style
snapback.jpg (4524 bytes)
Snap Back Cover
(for Panel Receptacles)

Panel receptacles are available in both male and female in a multitude of colors. These allow for panels to be constructed providing a permanent connection means between the generator set and the cam connecorized generator cables. The "Double Set Screw" and "Threaded Stud" designs allow for the creation of both load and sevice side connections with greater design flexibility.

femtofem.jpg (3631 bytes)
Female to Female
mtom.jpg (4504 bytes)
Male to Male
ffmtt.jpg (5441 bytes)
Female-Female-Male
mmfpt.jpg (4156 bytes)
Male-Male-Female
3fer.jpg (5979 bytes)
3 Fer
 


mtapp@gencable.com>
Copyright ©2009 Gencable.com.  All rights reserved.